pH electrodes for measurements in aqueous and non-aqueous media
DG electrodes are used for pH measurement and titration in difficult samples, low ionic and non-aqueous media.

DM electrodes with silver and platinum rings are suitable for redox titration with and without pH change, ...
pH electrodes for measurements in aqueous and non-aqueous media
DG electrodes are used for pH measurement and titration in difficult samples, low ionic and non-aqueous media.

DM electrodes with silver and platinum rings are suitable for redox titration with and without pH change, e.g. argentometry and Karl Fischer titration.

Plug & Play capable electrodes are automatically recognised by METTLER-TOLEDO pH meters and electrode type, serial number, calibration data and operating hours can be read out and processed by the software.
DGi111-SC: For pH measurement and acid/base titration in aqueous media. With S12 screw cap and detachable cable. ARGENTHAL? reference system. With Plug & Play functionality.

DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL? reference system.

DGi115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S12 screw cap and ARGENTHAL? reference system. With Plug & Play functionality.

DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL?/LiCl reference system.

DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL?/LiCl reference system.
PN Manuf. PN Supplier Electrode head Length~mm PK Range~pH Temp. range~°C Type General Price Quantity Status Add
7623825 51109504 Mettler-Toledo GmbH (Waagen) S12 149.5 1 0…14 0…100 DGi115-SC 850.00 EU Search 20 Days
6268472 51109505 Mettler-Toledo GmbH (Waagen) S12 149.5 1 0…12 0…100 DGi116-Solvent 939.71 EU Search Please contact us
7650134 51109500 Mettler-Toledo GmbH (Waagen) S12 149.5 1 0…14 0…80 DGi111-SC 719.12 EU Search Please contact us
7661899 51109506 Mettler-Toledo GmbH (Waagen) S12 185.1 1 1…11 0…100 DGi117-Water 1316.18 EU Search Please contact us